Ningbo SENYA Pneumatic Technology Co., Ltd. (SENYA)
  • 
  • Home
  • Products +
  • Applications +
  • Custom Integration
  • About Us +
  • Videos
  • Contact
  • Products
  • Air Preparation Units (FRL Units)
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
Products
  • Solenoid Valves
  • Pneumatic Fittings
  • Air Preparation Units (FRL Units)
  • Pneumatic Cylinders
  • Pneumatic Valves
Applications
  • Industrial Dust Collection
  • Heat Transfer Machinery
  • Tire Manufacturing Equipment
  • Agricultural Machinery
  • Pneumatic Polishing Systems
  • Water Flow Control Systems
  • Industrial Automation
  • Exhaust Ventilation System
PDF icon SENYA English Catalog PDF icon SENYA Company Introduction
Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
AC Series

Filter Regulator Lubricator Unit (FRL Unit)

3-in-1 air preparation unit for filtering, regulating and lubricating compressed air to ensure optimal performance in pneumatic systems
  • Compressed Air Treatment Unit/Air Preparation Unit
  • Port Size: 1/4"–1"
  • Filtration Accuracy: 40µm (5µm, 1µm optional)
  • Working Temperature: 5℃ to 60℃
Request a Quote
PDF icon
Features
  • Integrated design combining air filtration, regulation, and lubrication
  • Pressure adjustment knob with locking nut for precise and tamper-proof control
  • Analog ring-pressure gauge that is clear and easy to read
  • The filtered water is collected in the water cup, and the metal housing protects the cup against physical impact
  • Optional manual or automatic drainage configuration
  • Filter accuracy available in 1μm, 5μm, and 40μm levels
  • Compact and easy to install and use
  • Push-in automatic locking structure prevents adjustment deviation caused by external interference
  • Low pressure drop and high water separation efficiency
  • Aluminum protective shell for effective impact resistance
Specifications
Category FRL Units (Filter+Regulator+Lubricator)
Operating pressure 0-1.0MPa
Filtration accuracy 40µm (5µm, 1µm optional)
Working temperature 5℃ to 60℃
Port size 1/4"–1"
Related Air Preparation Units (FRL Units)
  • Filter Regulator Unit (FR Unit), AD Series
  • Filter Regulator Unit (FR Unit), AW Series
  • Stainless Steel Air Preparation Unit, SS Series
  • Filter Regulator Lubricator Unit (FRL Unit), AB Series
  • Filter Regulator Lubricator Unit (FRL Unit), AC Series
Why Choose SENYA?
  • High cost-effectiveness: Mass production reduces costs, saving 30%-50% compared to imported brands
  • Flexible customization: SENYA provides you with drawing/sample development to meet custom requirements (e.g., high-temperature or explosion-proof)
  • Factory inspection support: Customers are welcome to visit our production facilities and observe our production process and quality control procedures to verify our capabilities firsthand
Other Categories
View All
  • Pneumatic Cylinders
    Pneumatic Cylinders
  • Pneumatic Valves
    Pneumatic Valves
  • Solenoid Valves
    Solenoid Valves
  • Pneumatic Fittings
    Pneumatic Fittings
Specialized in Solenoid Valves &
Pneumatic Components Manufacturing
SENYA specializes in the engineering and manufacturing of solenoid valves and pneumatic components. With strong R&D capabilities and advanced production facilities, we develop standard and customized solutions to meet demanding industrial requirements. Our strict quality system includes 30 quality inspections and performance tests, ensuring every product delivers long-term reliability.
    1. Icon
      2004

      SENYA Was Founded

    1. Icon
      2,000+

      Standard Components in Stock

    1. Icon
      5,000,000+

      Units Produced Annually

Which air preparation unit model is the most cost-effective for a regular factory?

We recommend the AC series FRL Unit, which combines air filtration, regulation, and lubrication functions with high cost-effectiveness.

How to deal with a high humidity workshop environment?

We recommend using the AW-D series automatic drainage type, which has an electronic drain valve (EDV) to discharge accumulated water automatically, keeping pneumatic systems dry and reliable.

How often should the filter be replaced?

Replace the filter every 6–12 months in normal environments, or every 3–6 months under heavy dust or humidity.

Products
  • Solenoid Valves
  • Pneumatic Fittings
  • Air Preparation Units (FRL Units)
  • Pneumatic Cylinders
  • Pneumatic Valves
Applications
  • Industrial Dust Collection
  • Heat Transfer Machinery
  • Tire Manufacturing Equipment
  • Agricultural Machinery
  • Pneumatic Polishing Systems
Quick Link
  • About Us
  • Manufacturing
  • Why Choose Us
  • Become a Distributor
  • FAQs
Ningbo SENYA Pneumatic Technology Co., Ltd. (SENYA)
  • John
    1. info@nbsenya.com
    2. nbfh19941220@gmail.com
  • +86-574-88951829
  • +86-18857405853
  • +86-18857405853
Supported by ETW International Inc. USA